Issue212

Issue Title Requirement for abbreviated SCD in confirm
Document: GIST Protocol Specification v12 Section: 4.4.1, 5.2.2
Category: Technical Priority: Should Fix
Status: No Discussion

Created on 2007-03-28.09:56:03 by reh, last changed 2007-03-28.09:57:05.

Messages
msg586 Author: reh Date: 2007-03-28.09:57:05
Presumably, the simplest solution is that the SCD in the Confirm (containing
only the MA-hold time) is taken as authoritative, overwriting any value from
previous messages.
msg585 Author: reh Date: 2007-03-28.09:56:03
The text in 4.4.1 states that an abbreviated SCD is needed in the first confirm
on an MA, but leaves (slightly) unclear what it should contain and what happens
if the information does not match the original Query.
History
Date User Action Args
2007-03-28 09:57:05rehsetmessages: + msg586
2007-03-28 09:56:03rehcreate